diff options
Diffstat (limited to 'tests/test_stanza_xep_0323.py')
-rw-r--r-- | tests/test_stanza_xep_0323.py | 42 |
1 files changed, 21 insertions, 21 deletions
diff --git a/tests/test_stanza_xep_0323.py b/tests/test_stanza_xep_0323.py index 405245b5..95fb138b 100644 --- a/tests/test_stanza_xep_0323.py +++ b/tests/test_stanza_xep_0323.py @@ -6,7 +6,7 @@ import slixmpp.plugins.xep_0323 as xep_0323 namespace='sn' class TestSensorDataStanzas(SlixTest): - + def setUp(self): pass @@ -171,7 +171,7 @@ class TestSensorDataStanzas(SlixTest): iq['accepted']['seqnr'] = '2' self.check(iq,""" - <iq type='result' + <iq type='result' from='device@clayster.com' to='master@clayster.com/amr' id='2'> @@ -193,7 +193,7 @@ class TestSensorDataStanzas(SlixTest): iq['rejected']['error'] = 'Access denied.' self.check(iq,""" - <iq type='error' + <iq type='error' from='device@clayster.com' to='master@clayster.com/amr' id='4'> @@ -250,7 +250,7 @@ class TestSensorDataStanzas(SlixTest): <fields xmlns='urn:xmpp:iot:sensordata' seqnr='1'> <node nodeId='Device02'> <timestamp value='2013-03-07T16:24:30'> - <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> + <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> </timestamp> </node> </fields> @@ -269,7 +269,7 @@ class TestSensorDataStanzas(SlixTest): <fields xmlns='urn:xmpp:iot:sensordata' seqnr='1'> <node nodeId='Device02'> <timestamp value='2013-03-07T16:24:30'> - <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> + <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> </timestamp> </node> <node nodeId='EmptyDevice'/> @@ -314,7 +314,7 @@ class TestSensorDataStanzas(SlixTest): <fields xmlns='urn:xmpp:iot:sensordata' seqnr='1'> <node nodeId='Device02'> <timestamp value='2013-03-07T16:24:30'> - <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> + <numeric name='Temperature' momentary='true' automaticReadout='true' value='-12.42' unit='K'/> </timestamp> </node> <node nodeId='EmptyDevice'/> @@ -323,18 +323,18 @@ class TestSensorDataStanzas(SlixTest): </node> <node nodeId='Device77'> <timestamp value='2013-05-03T12:00:01'> - <numeric name='Temperature' historicalDay='true' value='-12.42' unit='K'/> - <numeric name='Speed' historicalWeek='false' value='312.42' unit='km/h'/> - <string name='Temperature name' historicalMonth='true' value='Bottom oil'/> - <string name='Speed name' historicalQuarter='false' value='Top speed'/> - <dateTime name='T1' historicalYear='true' value='1979-01-01T00:00:00'/> - <dateTime name='T2' historicalOther='false' value='2000-01-01T01:02:03'/> - <timeSpan name='TS1' missing='true' value='P5Y'/> - <timeSpan name='TS2' manualEstimate='false' value='PT2M1S'/> - <enum name='top color' invoiced='true' value='red' dataType='string'/> - <enum name='bottom color' powerFailure='false' value='black' dataType='string'/> - <boolean name='Temperature real' historicalDay='true' value='false'/> - <boolean name='Speed real' historicalWeek='false' value='true'/> + <numeric name='Temperature' historicalDay='true' value='-12.42' unit='K'/> + <numeric name='Speed' historicalWeek='false' value='312.42' unit='km/h'/> + <string name='Temperature name' historicalMonth='true' value='Bottom oil'/> + <string name='Speed name' historicalQuarter='false' value='Top speed'/> + <dateTime name='T1' historicalYear='true' value='1979-01-01T00:00:00'/> + <dateTime name='T2' historicalOther='false' value='2000-01-01T01:02:03'/> + <timeSpan name='TS1' missing='true' value='P5Y'/> + <timeSpan name='TS2' manualEstimate='false' value='PT2M1S'/> + <enum name='top color' invoiced='true' value='red' dataType='string'/> + <enum name='bottom color' powerFailure='false' value='black' dataType='string'/> + <boolean name='Temperature real' historicalDay='true' value='false'/> + <boolean name='Speed real' historicalWeek='false' value='true'/> </timestamp> </node> </fields> @@ -342,7 +342,7 @@ class TestSensorDataStanzas(SlixTest): """ ) - + def testTimestamp(self): msg = self.Message(); @@ -386,8 +386,8 @@ class TestSensorDataStanzas(SlixTest): self.check(msg,emptyStringIdXML) msg['fields']['stringIds'] = "1" self.check(msg,emptyStringIdXML) - - + + suite = unittest.TestLoader().loadTestsFromTestCase(TestSensorDataStanzas) |